Emulating an Intermec 86xx On a 3400
Description
How do I set the Intermec 3400 to emulate an Intermec 86xx printer?
Solution
There are two possible ways to configure an Intermec 3400 for 86xx emulation: A Software command and Hardware Commands.
Software Command
Copy the following IPL syntax to port:
<STX><ESC>c0<ETX> for 10 mil, or
<STX><ESC>c1<ETX> for 15 mil.
Hardware Commands
- Power off the printer.
- Depress and hold down the Feed button while turning on the printer.
- Release the Feed button once labels begin to feed.
- On the Top Bank of Dip Switches, turn switch numbers 1 and 3 on, and number 2 off.
- Choose the following settings.
- 86xx; 10mil; 4 on
- 86xx; 15mil; 4 & 5 on
- Advanced; 5mil; 4 & 5 off
- Advanced; 2.5mil; 5 on
- Press feed/pause button.
- Verify that the correct settings are enabled via the configuration label that prints.
-
Turn the printer off and back on.
Article Number
2009001
Versions
All versions of Loftware
Environment