Error Setting Drop Directory: ActiveX Client Control
Description
When attempting to define the drop directory property for the ActiveX Client Control This provides the functionality to connect to the LPS through a socket connection, similar to Loftware's On-Demand Print Client and Status Client. This allows users to get Job Status information, send files faster, and even send files between different networks., the following message is generated:
Explanation
This error occurs when there is not a status folder in the Drop Directory that is specified on the Properties Page of the ActiveX Client Control.
Solution
If you proceed and try to launch the VB program, a Visual Basic System Error is generated and the program crashes. This problem may be resolved one of two ways
Method 1
- Create a Status Folder in the Drop Directory listed in the Properties dialog box for the ActiveX Client Control
Method 2
- Open the Loftware Print Server Configuration Utility.
- Look at the Directories Tab, and the Base: path listed under the Working Directories section (Example: C:\Program Files\Loftware Labeling\WDDrop)
-
Ensure that the Base Directory listed here matches the Drop Directory listed on the Properties Page for the ActiveX Client Control.
Article Number
2009310
Versions
All versions of Loftware Print Server family products that support Active X
Environment
Any supported LPS Family product environment