Devices Advanced Options for Eltron Devices

If the Family selected is Eltron or Family Driver, and the Model selected is EPL2Closed Eltron Printer Language, a printer language from Eltron then the Advanced Options tab displays the following options. Some options may not be relevant to some device models.

Advanced Options

Option Description Values

Send Options

Whether to send device options configured in Loftware Enterprise SP to the device, or to use the device options configured on the device. When this check box is cleared, the options that are configured on the device are disabled in Loftware Enterprise SP.

Cleared: Use device options configured on the device.

Selected: Send all device options configured in Loftware Enterprise SP to the device. (Default)

Form Number

Eltron printers have the ability to store multiple forms in memory. In order to store multiple forms, a unique name must be generated for each form. This option is used to provide a unique form name.

1 to 99

Label Taken Sensor

Whether the device detects if the printed label has been removed before the next one is printed.

Cleared: The device automatically prints the next label. (Default)

Selected: The device detects if the printed label has been removed before the next one is printed.

Form Backup

Whether the device retracts the label before printing.

Cleared: Do not retract the label before printing. (Default)

Selected: Retract the label before printing.

Sensor Reverse

Whether to reverse the Through Sensor Operation, which interprets a blockage of light as a gap. This option allows the through sensor to be used when printing transparent labels with a black stripe backing.

Cleared: Do not reverse the Through Sensor Operation. (Default)

Selected: Reverse the Through Sensor Operation.

Dispense Sensor

When selected, the device presents each label and waits for the label to be removed before continuing.

Cleared: The device automatically prints the next label. (Default)

Selected: The device presents each label and waits for the label to be removed before continuing.

Dispense Tap

When selected, the device presents each label and waits for the feed switch to be

pressed before printing the next label. This mode is commonly used when printing multiple copies of liner-free labels.

Cleared: The device automatically prints the next label. (Default)

Selected: The device presents each label and waits for the feed switch to be pressed before printing the next label.

Dump Mode

When selected, the device is set in diagnostic dump mode.

Cleared: The device is not set in diagnostic dump mode. (Default)

Selected: The device is set in diagnostic dump mode.

Send Width

This option should be selected when labels narrower than the print head are

printed. If the label width equals the print head width, clear the check box for this option and the printer automatically centers the printing of the label.

Cleared: The device automatically centers the printing of the label.

Selected: Send the width of the label to the printer. (Default)

Device Contact Read Retry Attempts Source

When Loftware Enterprise SP requests information from a device and does not receive a response, you can specify the maximum number of times that Loftware Enterprise SP should repeat the request. If the maximum number of retry attempts is made without receiving a response, Loftware Enterprise SP reports an error.

This option allows you to configure whether the number of retry attempts is managed via a global setting or a value that you customize for this device.

Tip: You can view the value of the global setting in System System Managementby clicking System Properties. For Namespace, enter deviceManagement to filter the list, and then view the system key named connection.readRetry.count.

Use Global Setting: The maximum number of retry attempts is specified by a global system key. (Default)

Custom Value: The Read Retry Attempts option is displayed and overrides the global setting.

Device Contact Read Wait Time Source

When Loftware Enterprise SP requests information from a device, you can specify how long Loftware Enterprise SP waits to receive a response from the device before repeating the request or reporting an error.

This option allows you to configure whether the wait time is managed via a global setting or a value that you customize for this device.

Tip: You can view the value of the global setting in System System Managementby clicking System Properties. For Namespace, enter deviceManagement to filter the list, and then view the system key named connection.readWait.time_msec. The value is in milliseconds.

Use Global Setting: The wait time is specified by a global system key. (Default)

Custom Value: The Read Wait Time option is displayed and overrides the global setting.

Print Label As Image

Whether Loftware Enterprise SP should render the entire label as an image or generate each field individually.

If individually, the field is rendered natively by the device if possible. If the device does not support native rendering of the field, then Loftware Enterprise SP generates an image for the field.

: Render fields individually. (Default if supported for device)

: Render entire label as an image.

Advanced Troubleshooting

Option Description Values
Advanced Troubleshooting

Whether to display advanced troubleshooting options, including options for print stream scripting.

Disabled: Do not display advanced troubleshooting options, and do not run a print stream script for this device connection. (Default)